J Biomed Opt ; 28(12): 125002, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38074216

RESUMO

Significance: Speckle contrast analysis is the basis of laser speckle imaging (LSI), a simple, inexpensive, noninvasive technique used in various fields of medicine and engineering. A common application of LSI is the measurement of tissue blood flow. Accurate measurement of speckle contrast is essential to correctly measure blood flow. Variables, such as speckle grain size and camera pixel size, affect the speckle pattern and thus the speckle contrast. Aim: We studied the effects of spatial correlation among adjacent camera pixels on the resulting speckle contrast values. Approach: We derived a model that accounts for the potential correlation of intensity values in the common experimental situation where the speckle grain size is larger than the camera pixel size. In vitro phantom experiments were performed to test the model. Results: Our spatial correlation model predicts that speckle contrast first increases, then decreases as the speckle grain size increases relative to the pixel size. This decreasing trend opposes what is observed with a standard speckle contrast model that does not consider spatial correlation. Experimental data are in good agreement with the predictions of our spatial correlation model. Conclusions: We present a spatial correlation model that provides a more accurate measurement of speckle contrast, which should lead to improved accuracy in tissue blood flow measurements. The associated correlation factors only need to be calculated once, and open-source software is provided to assist with the calculation.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Hemodinâmica , Imagens de Fantasmas , Software
2.
PLoS One ; 18(12): e0294075, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38096242

RESUMO

BACKGROUND: Obesity is a global health concern and risk factor for cardiovascular disease. The assessment of central blood pressure (cBP) has been shown to improve prediction of cardiovascular events. However, few studies have investigated the impact of obesity on cBP in adults, and invasive data on this issue are lacking. This study aimed to evaluate cBP differences between patients with and without obesity, identify cBP determinants, and evaluate the accuracy of the algorithm Antares for non-invasive cBP estimation. METHODS: A total of 190 patients (25% female; 39% with BMI ≥30kg/m2; age: 67±12 years) undergoing elective cardiac catheterization were included. cBP was measured invasively and simultaneously estimated non-invasively using the custo screen 400 device with integrated Antares algorithm. RESULTS: No significant cBP differences were found between obese and non-obese patients. However, females, especially those with obesity, had higher systolic cBP compared to males (P<0.05). Multiple regression analysis showed that brachial mean arterial pressure, pulse pressure, BMI, and heart rate predicted cBP significantly (adjusted R2 = 0.82, P<0.001). Estimated cBP correlated strongly with invasive cBP for systolic, mean arterial, and diastolic cBP (r = 0.74-0.93, P<0.001) and demonstrated excellent accuracy (mean difference <5 and SD <8 mmHg). CONCLUSIONS: This study discovered no significant difference in cBP between obese and non-obese patients. However, it revealed higher cBP values in women, especially those with obesity, which requires further investigation. Additionally, the study highlights Antares' effectiveness in non-invasively determining cBP in obese individuals. This could improve the diagnosis and treatment of hypertension in this special patient population.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Pressão Sanguínea/fisiologia , Obesidade/complicações , Obesidade/diagnóstico , Técnicas de Diagnóstico Cardiovascular
3.
Rev. esp. cardiol. (Ed. impr.) ; 76(10): 759-766, Octubre 2023. tab, graf
Artigo em Inglês, Espanhol | IBECS | ID: ibc-226137

RESUMO

Introducción y objetivos: La nefropatía inducida por contraste (NIC) es una potencial complicación de los procedimientos que requieren la administración de medio de contraste yodado. El RenalGuard, que suministra una adecuada hidratación combinada con diuresis inducida por furosemida, es una alternativa a las estrategias convencionales de hidratación. Según la literatura disponible, la evidencia sobre el RenalGuard no es concluyente, por lo que hemos realizado un metanálisis utilizando una construcción bayesiana. Métodos Se realizaron búsquedas en Medline, Cochrane Library y Web of Science de ensayos aleatorizados de RenalGuard frente a estrategias estándar de hidratación periprocedimiento. El objetivo primario fue el desarrollo de NIC. Los objetivos secundarios fueron muerte por cualquier causa, shock cardiogénico, edema agudo de pulmón (EAP) e insuficiencia renal que requería terapia de reemplazo renal. Para cada resultado se calculó un riesgo relativo (RR) con el correspondiente intervalo de credibilidad del 95% (ICr95%). Registro número CRD42022378489 en PROSPERO database. Resultados Se incluyeron 6 estudios. El RenalGuard se asoció con una reducción relativa significativa de NIC (mediana de RR=0,54; ICr95%, 0,31-0,86) y EAP (mediana de RR=0,35; 95%ICr, 0,12-0,87). No se observaron diferencias significativas para los otros parámetros secundarios [muerte por cualquier causa (RR=0,49; ICr95%, 0,13-1,08), shock cardiogénico (RR=0,06; ICr95%, 0,00-1,91), terapia de reemplazo renal (RR=0,52; ICr95%, 0,18-1,18)]. El análisis Bayesiano también mostró que el RenalGuard obtuvo una alta probabilidad de posicionarse primero con respecto a todos los objetivos secundarios. Estos resultados fueron consistentes en múltiples análisis de sensibilidad. Conclusiones En los pacientes sometidos a procedimientos cardiovasculares percutáneos, el RenalGuard se asoció con un menor riesgo de NIC y EAP. (AU)


Introduction and objectives: Contrast-associated acute kidney injury (CA-AKI) is a potential complication of procedures requiring administration of iodinated contrast medium. RenalGuard, which provides real-time matching of intravenous hydration with furosemide-induced diuresis, is an alternative to standard periprocedural hydration strategies. The evidence on RenalGuard in patients undergoing percutaneous cardiovascular procedures is sparse. We used a Bayesian framework to perform a meta-analysis of RenalGuard as a CA-AKI preventive strategy. Methods We searched Medline, Cochrane Library and Web of Science for randomized trials of RenalGuard vs standard periprocedural hydration strategies. The primary outcome was CA-AKI. Secondary outcomes were all-cause death, cardiogenic shock, acute pulmonary edema, and renal failure requiring renal replacement therapy. A Bayesian random-effect risk ratio (RR) with corresponding 95% credibility interval (95%CrI) was calculated for each outcome. PROSPERO database number CRD42022378489. Results Six studies were included. RenalGuard was associated with a significant relative reduction in CA-AKI (median RR, 0.54; 95%CrI, 0.31-0.86) and acute pulmonary edema (median RR, 0.35; 95%CrI, 0.12-0.87). No significant differences were observed for the other secondary endpoints [all-cause death (RR, 0.49; 95%CrI, 0.13-1.08), cardiogenic shock (RR, 0.06; 95%CrI, 0.00-1.91), and renal replacement therapy (RR, 0.52; 95%CrI, 0.18-1.18)]. The Bayesian analysis also showed that RenalGuard had a high probability of ranking first for all the secondary outcomes. These results were consistent in multiple sensitivity analyses. Conclusions In patients undergoing percutaneous cardiovascular procedures, RenalGuard was associated with a reduced risk of CA-AKI and acute pulmonary edema compared with standard periprocedural hydration strategies. (AU)


Assuntos
Humanos , Procedimentos Cirúrgicos Cardiovasculares/métodos , Cirurgia Torácica/instrumentação , Cirurgia Torácica/métodos , Técnicas de Diagnóstico Cardiovascular/instrumentação
4.
Nanoscale ; 15(23): 9993-10003, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37265264

RESUMO

Upconversion broadband white light emission driven by low-power near-infrared (NIR) lasers has been reported for many materials, but the mechanisms and effects related to this phenomenon remain unclear. Herein, we investigate the origin of laser-induced continuous white light emission in synthesized nanoparticles (Gd0.89Yb0.10Er0.01)2O3 and a mechanical mixture of commercial oxides with the same composition 89% Gd2O3, 10% Yb2O3, and 1% Er2O3. We report their photophysical features with respect to sample compactness, laser irradiation (wavelength, power density, excitation cycles), pressure, temperature, and temporal dynamics. Despite the sensitizer (Yb3+) and activator (Er3+) being in different particles for the mechanical mixture, efficient discrete and continuous upconversion emissions were observed. Furthermore, the synthesized nanoparticles were developed as primary luminescent thermometers (upon excitation at NIR) in the 299-363 K range, using the Er3+ upconversion 2H11/2 → 4I15/2/4S3/2 → 4I15/2 intensity ratio. They were also operating as secondary ones in the 1949-3086 K, based on the blackbody distribution of the observed white light emission. Our findings provide important insights into the mechanisms and effects related to the transition from discrete to continuous upconversion emissions with potential applications in remote temperature sensing.


Assuntos
Termometria , Fototerapia , Luz , Temperatura , Técnicas de Diagnóstico Cardiovascular
5.
Radiología (Madr., Ed. impr.) ; 65(3): 269-284, May-Jun. 2023. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-221008

RESUMO

La resonancia magnética se ha convertido en técnica de imagen de primera línea en muchas situaciones clínicas. El número de pacientes portadores de dispositivos cardiovasculares, como los dispositivos cardiovasculares electrónicos implantables, ha crecido de modo exponencial. Aunque se han descrito complicaciones y efectos adversos cuando estos pacientes se someten a exploraciones de resonancia magnética, la evidencia clínica actual respalda la seguridad de realizar estos estudios cuando se cumplen unas normas y recomendaciones dirigidas a minimizar los posibles riesgos. El Grupo de Trabajo de Cardiorresonancia Magnética y Cardiotomografía Computarizadas de la Sociedad Española de Cardiología (SEC-GT CRMTC), la Asociación del Ritmo Cardiaco de la Sociedad Española de Cardiología (SEC-Asociación del Ritmo Cardiaco de la Sociedad Española de Cardiología), la Sociedad Española de Radiología Médica (SERAM) y la Sociedad Española de Imagen Cardiotorácica (SEICAT) han elaborado el presente documento, que revisa la evidencia disponible en este campo y establece las recomendaciones necesarias para que los pacientes portadores de dispositivos cardiovasculares electrónicos implantables y otros dispositivos puedan acceder con seguridad a este instrumento diagnóstico.(AU)


Magnetic resonance has become a first-line imaging modality in various clinical scenarios. The number of patients with different cardiovascular devices, including cardiac implantable electronic devices, has increased exponentially. Although there have been reports of risks associated with exposure to magnetic resonance in these patients, the clinical evidence now supports the safety of performing these studies under specific conditions and following recommendations to minimize possible risks. This document was written by the Working Group on Cardiac Magnetic Resonance Imaging and Cardiac Computed Tomography of the Spanish Society of Cardiology (SEC-GT CRMTC), the Heart Rhythm Association of the Spanish Society of Cardiology (SEC-Heart Rhythm Association), the Spanish Society of Medical Radiology (SERAM), and the Spanish Society of Cardiothoracic Imaging (SEICAT). The document reviews the clinical evidence available in this field and establishes a series of recommendations so that patients with cardiovascular devices can safely access this diagnostic tool.(AU)


Assuntos
Humanos , Masculino , Feminino , Espectroscopia de Ressonância Magnética , Técnicas de Diagnóstico Cardiovascular , Equipamentos e Provisões , Técnicas e Procedimentos Diagnósticos , Segurança do Paciente , Marca-Passo Artificial , Desfibriladores Implantáveis , Radiologia , Consenso
6.
Sci Rep ; 13(1): 8803, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37258644

RESUMO

Diffuse correlation spectroscopy (DCS) is an optical technique that can be used to characterize blood flow in tissue. The measurement of cerebral hemodynamics has arisen as a promising use case for DCS, though traditional implementations of DCS exhibit suboptimal signal-to-noise ratio (SNR) and cerebral sensitivity to make robust measurements of cerebral blood flow in adults. In this work, we present long wavelength, interferometric DCS (LW-iDCS), which combines the use of a longer illumination wavelength (1064 nm), multi-speckle, and interferometric detection, to improve both cerebral sensitivity and SNR. Through direct comparison with long wavelength DCS based on superconducting nanowire single photon detectors, we demonstrate an approximate 5× improvement in SNR over a single channel of LW-DCS in the measured blood flow signals in human subjects. We show equivalence of extracted blood flow between LW-DCS and LW-iDCS, and demonstrate the feasibility of LW-iDCS measured at 100 Hz at a source-detector separation of 3.5 cm. This improvement in performance has the potential to enable robust measurement of cerebral hemodynamics and unlock novel use cases for diffuse correlation spectroscopy.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Hemodinâmica , Adulto , Humanos , Análise Espectral/métodos , Interferometria , Razão Sinal-Ruído
7.
Crit Care ; 27(1): 136, 2023 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-37031182

RESUMO

BACKGROUND: In patients on mechanical ventilation, positive end-expiratory pressure (PEEP) can decrease cardiac output through a decrease in cardiac preload and/or an increase in right ventricular afterload. Increase in central blood volume by fluid administration or passive leg raising (PLR) may reverse these phenomena through an increase in cardiac preload and/or a reopening of closed lung microvessels. We hypothesized that a transient decrease in PEEP (PEEP-test) may be used as a test to detect volume responsiveness. METHODS: Mechanically ventilated patients with PEEP ≥ 10 cmH2O ("high level") and without spontaneous breathing were prospectively included. Volume responsiveness was assessed by a positive PLR-test, defined as an increase in pulse-contour-derived cardiac index (CI) during PLR ≥ 10%. The PEEP-test consisted in reducing PEEP from the high level to 5 cmH2O for one minute. Pulse-contour-derived CI (PiCCO2) was monitored during PLR and the PEEP-test. RESULTS: We enrolled 64 patients among whom 31 were volume responsive. The median increase in CI during PLR was 14% (11-16%). The median PEEP at baseline was 12 (10-15) cmH2O and the PEEP-test resulted in a median decrease in PEEP of 7 (5-10) cmH2O, without difference between volume responsive and unresponsive patients. Among volume responsive patients, the PEEP-test induced a significant increase in CI of 16% (12-20%) (from 2.4 ± 0.7 to 2.9 ± 0.9 L/min/m2, p < 0.0001) in comparison with volume unresponsive patients. In volume unresponsive patients, PLR and the PEEP-test increased CI by 2% (1-5%) and 6% (3-8%), respectively. Volume responsiveness was predicted by an increase in CI > 8.6% during the PEEP-test with a sensitivity of 96.8% (95% confidence interval (95%CI): 83.3-99.9%) and a specificity of 84.9% (95%CI 68.1-94.9%). The area under the receiver operating characteristic curve of the PEEP-test for detecting volume responsiveness was 0.94 (95%CI 0.85-0.98) (p < 0.0001 vs. 0.5). Spearman's correlation coefficient between the changes in CI induced by PLR and the PEEP-test was 0.76 (95%CI 0.63-0.85, p < 0.0001). CONCLUSIONS: A CI increase > 8.6% during a PEEP-test, which consists in reducing PEEP to 5 cmH2O, reliably detects volume responsiveness in mechanically ventilated patients with a PEEP ≥ 10 cmH2O. Trial registration ClinicalTrial.gov (NCT 04,023,786). Registered July 18, 2019. Ethics Committee approval CPP Est III (N° 2018-A01599-46).


Assuntos
Volume Sanguíneo , Débito Cardíaco , Hidratação , Coração , Respiração com Pressão Positiva , Respiração Artificial , Humanos , Volume Sanguíneo/fisiologia , Débito Cardíaco/fisiologia , Técnicas de Diagnóstico Cardiovascular , Técnicas de Diagnóstico do Sistema Respiratório , Hidratação/métodos , Coração/fisiopatologia , Hemodinâmica , Respiração com Pressão Positiva/efeitos adversos , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Curva ROC
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 828-831, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085644

RESUMO

This paper presents a new method of measuring non-invasive blood pressure at the radial artery based on oscillometry and tonometry. A localized capacitive tactile sensor array is used with a novel algorithm based on waveform features for optimizing oscillometry ratios. A novel tonometer is presented with typically 1% base measurement error, with sensor errors compensated using a custom error model, and applied to blood pressure measurement at the radial artery. The tonometer gives a direct arterial waveform, and uses a manual pressure sweep to determine blood pressure. Key points on the oscillogram are correlated with optimal ratios for minimizing mean errors and standard deviation for an individual. This paper details an initial assessment into the dominant sources of error, for the purpose of determining feasibility and directing future research. Over a limited clinical trial of Np = 20, No = 180, the reported BP accuracy is MAE = 0.61/0.38mmHg and 1SD = 7.14/5.91mmHg for systolic and diastolic measurements respectively. The average load on the patient is in the order of 5N, compared with around 1000N for a brachial cuff, which represents a clear improvement in patient comfort. This is a positive result, indicating larger scale performance within AAMI and BHS standards, and stands as a useful benchmark for further development of the system into a clinical product for rapid and comfortable BP measurement. Clinical Relevance This paper demonstrated that direct tonometry can measure blood pressure if sensor error is compensated by the designer. This method uses 200x less load than conventional cuffs suitable for long term and supine use.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Artéria Radial , Pressão Sanguínea , Determinação da Pressão Arterial , Humanos , Oscilometria
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2898-2901, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085836

RESUMO

Blood pressure (BP) is a key parameter in critical care and in cardiovascular disease management. BP is typically measured via cuff-based oscillometry. This method is highly inaccurate in hypo- and hypertensive patients. Improvements are difficult to achieve because oscillometry is not yet fully understood; many assumptions and uncertainties exist in models describing the process by which arterial pulsations become expressed within the cuff signal. As a result, it is also difficult to estimate other parameters via the cuff such as arterial stiffness, cardiac output and pulse wave velocity (PWV)-BP calibration. Many research modalities have been employed to study oscillometry (ultrasound, computer simulations, ex-vivo studies, measurement of PWV, mechanical analysis). However, uncertainties remain; additional investigation modalities are needed. In this study, we explore the extent to which MRI can help investigate oscillometric assumptions. Four healthy volunteers underwent a number of MRI scans of the upper arm during cuff inflation. It is found that MRI provides a novel perspective over oscillometry; the artery, surrounding tissue, veins and the cuff can be simultaneously observed along the entire length of the upper arm. Several existing assumptions are challenged: tissue compression is not isotropic, arterial transmural pressure is not uniform along the length of the cuff and propagation of arterial pulsations through tissue is likely impacted by patient-specific characteristics (vasculature position and tissue composition). Clinical Relevance- The cuff interaction with the vasculature is extremely complex; existing models are oversimplified. MRI is a valuable tool for further development of cuff-based physiological measurements.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Análise de Onda de Pulso , Humanos , Imageamento por Ressonância Magnética , Oscilometria , Registros
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 5008-5011, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085902

RESUMO

Magnetic Resonance Thermometry Imaging (MRTI) holds great potential in laser ablation (LA) monitoring. It provides the real-time multidimensional visualization of the treatment effect inside the body, thus enabling accurate intraoperative prediction of the thermal damage induced. Despite its great potential., thermal maps obtained with MRTI may be affected by numerous artifacts. Among the sources of error producing artifacts in the images., the cavitation phenomena which could occur in the tissue during LA induces dipole-structured artifacts. In this work., an analysis of the cavitation artifacts occurring during LA in a gelatin phantom in terms of symmetry in space and symmetry of temperature values was performed. Results of 2 Wand 4 W laser power were compared finding higher symmetry for the 2 W case in terms of both dimensions of artifact-lobes and difference in temperature values extracted in specular pixels in the image. This preliminary investigation of artifact features may provide a step forward in the identification of the best strategy to correct and avoid artifact occurrence during thermal therapy monitoring. Clinical Relevance- This work presents an analysis of cavitation artifacts in MRTI from LA which must be corrected to avoid error in the prediction of thermal damage during LA monitoring.


Assuntos
Terapia a Laser , Termometria , Artefatos , Técnicas de Diagnóstico Cardiovascular , Imageamento por Ressonância Magnética
16.
Dtsch Med Wochenschr ; 147(9): 528-537, 2022 04.
Artigo em Alemão | MEDLINE | ID: mdl-35468634

RESUMO

Cardiovascular magnetic resonance (CMR) has become an accepted method for noninvasive imaging in cardiology. As part of a multimodality concept, this method can contribute valuable diagnostic aspects, often even as a first-choice method in a variety of diseases. Currently the availability is still limited, but the increasing time efficiency, technical stability and the growing competence will lead to more guideline-compliant use. The increase of CMR inclusion into guidelines of various societies is mainly based on the unique selling point of CMR, which is noninvasive myocardial tissue differentiation. In addition to efficient ischemia diagnosis, the ability to differentiate active from chronic inflammatory processes as well as the identification of reversible and irreversible damage are some aspects CMR can offer. New developments are sequences which allow for a parametric assessment of myocardial tissue based on T1- and T2-relaxation times. This is especially useful if the exact pathophysiology is unclear, as it is often the case in left ventricular hypertrophy for example. Next to the noninvasive myocardial tissue characterization CMR allows for quantitative hemodynamic assessment of the heart and the related pathologies. Flows as well as gradients can be quantified based on 2D-flow-sequences. New 4D-sequences are aiming to further characterize blood flow in the heart and the great vessels beyond flow volume and gradients. As with any diagnostic method a qualified application is crucial. In recent years, the technique itself has become much more stable and consensus recommendations of the Society for Cardiovascular Magnetic Resonance are available for the main indications, both for the MRI scan procedure and for the evaluation. Appropriate qualifications and certification opportunities are offered both nationally and internationally.


Assuntos
Coração , Imageamento por Ressonância Magnética , Técnicas de Diagnóstico Cardiovascular , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Miocárdio
17.
Am J Obstet Gynecol ; 226(2S): S988-S1005, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35177225

RESUMO

Gestational hypertension and preeclampsia are the 2 main types of hypertensive disorders in pregnancy. Noninvasive maternal cardiovascular function assessment, which helps obtain information from all the components of circulation, has shown that venous hemodynamic dysfunction is a feature of preeclampsia but not of gestational hypertension. Venous congestion is a known cause of organ dysfunction, but its potential role in the pathophysiology of preeclampsia is currently poorly investigated. Body water volume expansion occurs in both gestational hypertension and preeclampsia, and this is associated with the common feature of new-onset hypertension after 20 weeks of gestation. Blood pressure, by definition, is the product of intravascular volume load and vascular resistance (Ohm's law). Fundamentally, hypertension may present as a spectrum of cardiovascular states varying between 2 extremes: one with a predominance of raised cardiac output and the other with a predominance of increased total peripheral resistance. In clinical practice, however, this bipolar nature of hypertension is rarely considered, despite the important implications for screening, prevention, management, and monitoring of disease. This review summarizes the evidence of type-specific hemodynamic profiles in the latent and clinical stages of hypertensive disorders in pregnancy. Gestational volume expansion superimposed on an early gestational closed circulatory circuit in a pressure- or volume-overloaded condition predisposes a patient to the gradual deterioration of overall circulatory function, finally presenting as gestational hypertension or preeclampsia-the latter when venous dysfunction is involved. The eventual phenotype of hypertensive disorder is already predictable from early gestation onward, on the condition of including information from all the major components of circulation into the maternal cardiovascular assessment: the heart, central and peripheral arteries, conductive and capacitance veins, and body water content. The relevance of this approach, outlined in this review, openly invites for more in-depth research into the fundamental hemodynamics of gestational hypertensive disorders, not only from the perspective of the physiologist or the scientist, but also in assistance of clinicians toward understanding and managing effectively these severe complications of pregnancy.


Assuntos
Hemodinâmica/fisiologia , Hipertensão Induzida pela Gravidez/fisiopatologia , Pré-Eclâmpsia/fisiopatologia , Técnicas de Diagnóstico Cardiovascular , Feminino , Humanos , Placentação/fisiologia , Volume Plasmático/fisiologia , Gravidez , Resistência Vascular/fisiologia
19.
Sensors (Basel) ; 22(3)2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35161643

RESUMO

Non-invasive measurement of the arterial blood speed gives important health information such as cardio output and blood supplies to vital organs. The magnitude and change in arterial blood speed are key indicators of the health conditions and development and progression of diseases. We demonstrated a simple technique to directly measure the blood flow speed in main arteries based on the diffused light model. The concept is demonstrated with a phantom that uses intralipid hydrogel to model the biological tissue and an embedded glass tube with flowing human blood to model the blood vessel. The correlation function of the measured photocurrent was used to find the electrical field correlation function via the Siegert relation. We have shown that the characteristic decorrelation rate (i.e., the inverse of the decoherent time) is linearly proportional to the blood speed and independent of the tube diameter. This striking property can be explained by an approximate analytic solution for the diffused light equation in the regime where the convective flow is the dominating factor for decorrelation. As a result, we have demonstrated a non-invasive method of measuring arterial blood speed without any prior knowledge or assumption about the geometric or mechanic properties of the blood vessels.


Assuntos
Artérias , Hemodinâmica , Velocidade do Fluxo Sanguíneo , Técnicas de Diagnóstico Cardiovascular , Humanos , Imagens de Fantasmas
20.
Can J Cardiol ; 38(2): 225-233, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34737036

RESUMO

Nowhere is the influence of artificial intelligence (AI) likely to be more profoundly felt than in health care, from patient triage and diagnosis to surgery and follow-up. Over the medium-term, these effects will be more acute in the cardiovascular imaging context, in which AI models are already successfully performing at approximately human levels of accuracy and efficiency in certain applications. Yet, the adoption of unexplainable AI systems for cardiovascular imaging still raises significant legal and ethical challenges. We focus in particular on challenges posed by the unexplainable character of deep learning and other forms of sophisticated AI modelling used for cardiovascular imaging by briefly outlining the systems being developed in this space, describing how they work, and considering how they might generate outputs that are not reviewable by physicians or system programmers. We suggest that an unexplainable tendency presents 2 specific ethico-legal concerns: (1) difficulty for health regulators; and (2) confusion about the assignment of liability for error or fault in the use of AI systems. We suggest that addressing these concerns is critical for ensuring AI's successful implementation in cardiovascular imaging.


Assuntos
Inteligência Artificial , Cardiologia/legislação & jurisprudência , Doenças Cardiovasculares/diagnóstico , Aprendizado Profundo , Atenção à Saúde/ética , Técnicas de Diagnóstico Cardiovascular/ética , Cardiologia/ética , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...